RADIOGRAPHY TESTING (RT) → Industrial X-Ray Equipment
Dandong Aolong X-ray Equipment
XXG-3005 Directional X-ray
- The XXG-3005 x-ray flaw detector is equipped with a 300kV ceramic X-ray tube, ensuring stable and reliable high-energy output.
- At a 300kV operating voltage and a 600mm focal length, Aolong’s XXG-3005 Panoramic X-ray Flaw Detector can clearly penetrate 50mm thick Q235 steel, placing it at the forefront of similar equipment in China.
- The XXG-3005 Panoramic X-ray Flaw Detector utilizes an optimized 40+5° radiation angle design, ensuring a wide detection range while minimizing scattering interference.
For more details or to explore additional models, please feel free to contact us.
Industrial Portable X-ray System
Industrial Portable X-ray System EGM2 Series
RF-200EGM2/RF-250EGM2/RF-300EGM2
- Exposure timer settings are in 1-second increments.
- Equipped with a power saving mode (LOW mode).
- Optional software allows integration with the DDA digital detector.
The RF-EGM2 series combines excellent operability with robust construction. The X-ray generator uses a ceramic X-ray tube, boasting reliability backed by a proven track record of successful installations.
CHARACTERISTICS
Features
Ceramic X-Ray Tube
Uses highly reliable ceramic X-ray tubes.
Exposure Condition Memory
The microcomputerized control device allows instant recall of photographs and storage of exposure conditions.
Switch Button
To facilitate on-site work, the panel is operated with block-type switch buttons.
Simplicity and Ease
It features simplicity and ease of use to deliver real efficiency in on-site radiography operations.
Specification
| RF-300EGM2 | RF-250EGM2 | RF-200EGM2 | |
|---|---|---|---|
| Tube voltage | 130-300 kV, 2 kV steps | 110-250 kV, 2 kV steps | 70-200 kV, 2 kV steps |
| tube current | (STD mode) 5 mA (160 kV or higher) (LOW mode) ≈ 4 mA (160 kV or higher) |
(STD mode) 5 mA (140 kV or higher) (LOW mode) ≈ 4 mA (140 kV or higher) |
(STD mode) 5 mA (90 kV or higher) (LOW mode) ≈ 4 mA (90 kV or higher) |
| Duty |
1:1 (maximum 10 minutes, -10℃~45℃ | ||
| x-ray tube | Ceramic X-ray tube focal spot size (nominal value): 2.5 mm × 2.5 mm |
Ceramic X-ray tube focal spot size (nominal value): 2.0 mm × 2.0 mm |
|
| X-ray filter | 2 mm aluminum + 1 mm beryllium | ||
| power supply | Single-phase AC 190 V to 240 V, 50/60 Hz | ||
| Power capacity | (STD mode) 4.1 kVA (LOW mode) 3.0 kVA |
(STD mode) 3.7 kVA (LOW mode) 2.8 kVA |
(STD mode) 3.1 kVA (LOW mode) 2.4 kVA |
| Insulation method | SF6 insulating gas | ||
| Cooling method | forced air cooling | ||